Cable supports carrying large cables along a utility route

Huse pentru cleme SMC FRP

Explore product features and specifications. Share your drawing to discuss a tailored solution.

Huse pentru cleme SMC FRP

Un capac de carcasă de protecție fabricat din compozit din plastic armat cu fibră de sticlă SMC pentru cleme de linie electrică aeriană.

Dingchang / Sales Manager +86 17515190958
Get in touch

Description

Product Overview

Un capac de carcasă de protecție fabricat din compozit din plastic armat cu fibră de sticlă SMC pentru cleme de linie electrică aeriană.

Compared with conventional metal clamp covers of equivalent dimensions, the FRP clamp cover adopts high-performance fiberglass composite material to deliver excellent electrical insulation, corrosion-resistance and UV-aging resistance. It is designed to shield overhead line clamps against ultraviolet radiation, rain, salt-fog, dust and external mechanical impact. This product is well-suited for overhead distribution networks operating in coastal, saline-alkali, industrial-polluted and long-term outdoor exposure environments.

Final structural dimension, mounting interface, material performance grade and accessories shall be confirmed in accordance with the approved project specification.

Key Features

High-strength SMC fiberglass-reinforced plastic composite for outstanding insulation and anti-corrosion performance.

Adaptable to overhead distribution lines under coastal salt-fog, saline-alkali and heavily polluted outdoor conditions.

Integral moulded structure; sealed fit minimizes exposure of internal clamp hardware to ambient atmosphere.

Optimized wall thickness and reinforcing ribs to resist external mechanical impact and deformation.

Mounting interface, opening size and fixing configuration selected to match the corresponding line clamp dimensions.

Flame-retardant grade, UV-resistant additive and surface finish configured for the local installation environment.

Quality & testing

Standards and Testing

Domestic-market configurations shall comply with relevant requirements of GB/T 1404.1, GB/T 2570 and corresponding power-fitting standards.

Export-oriented configurations may reference IEC 61952 or other project-specified standards. Final compliance shall be subject to approved design, guaranteed performance values and agreed test documentation.

Routine tests may include:

Visual and dimensional inspection

Dielectric strength & insulation resistance test

Mechanical impact test

Fastening / assembly fit check

Appearance check after high-low temperature cycling test

Type tests, special environmental ageing tests and third-party inspection can be agreed prior to production upon request.

Applications & project requirements

Applications

Urban and rural overhead distribution networks

Coastal, salt-fog and saline-alkali power transmission sections

Industrial‑area overhead lines with chemical atmospheric pollution

Overhead lines requiring long-term outdoor anti-corrosion protection

Distribution-network upgrade projects for overhead fitting insulation improvement

New-energy power-plant overhead outgoing line systems

Selecting an FRP Clamp Cover

The service-life and protective effectiveness of the FRP clamp cover depend on matching dimensions with the actual line clamp, guaranteed material performance grade, local environmental conditions and operating voltage level.

Selection shall therefore be based on approved mechanical-dielectric data and on-site fitting dimension parameters rather than model designation alone.

Request a Quotation

Please provide applicable rated voltage, matched line-clamp type & dimension, required flame-retardant / anti-UV grade, applicable standard, installation environment conditions, supporting accessory requirements, quantity and project destination.

Discutați proiectul dvs

Share your drawing, quantity, application and delivery destination with our team.

Solicitați o cotație
Specifications & configuration

Review the available product information and project-specific configurations below.

View specifications →

Specifications & configuration

Product information for your technical review. Final dimensions and requirements are confirmed for the selected configuration.

Reference Specifications

Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.

Parameter Available Configuration
Type FRP clamp cover
Core material SMC fiberglass-reinforced plastic composite
Structure construction According to approved project drawing
Reference dimension range Custom-made to match line-clamp specification
Rated applicable voltage Project-specified (0.4kV-35kV typical)
Flame retardant class Custom grade as required
Complete model designation Confirmed according to selected construction
Guaranteed mechanical & dielectric performance Defined in approved technical data sheet
Mounting form Snap-fit / bolt-fastened, project-specified
Installation Outdoor overhead power line
Accessories Fasteners, sealing gaskets configured per approved specification

Reference performance

Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.

No. Parameter Name Unit Required Value Remarks
1 Volume Resistivity Ωm ≥10¹³ Acc.to GB/T 1410-2006/IEC 60093 1980
2 Flexural Strength Mpa ≥200 Acc.to GB1449 or ASTM D790
3 Impact Strength KJ/m² ≥120 Acc.to GB/T 1451-2005
4 Glass Fiber Volume Content % ≥30 Acc.to ASTM D3171
5 Degree of Cure % ≥95 Acc.to GB/T 2576
6 Electric Breakdown Strength KV/mm ≥10 Acc.to GB 1408 or IEC 243
7 Tracking Resistance V 600 GB/T 4207-2012/IEC 60112-2009
8 Water Absorption % ≤0.2 Acc.to GB1462 or ASTM D570
9 Flame Retardancy V-0 GB/T 2408-2008/IEC 60695-11-10:1999

Material and manufacturing

FRP advantages. Project-specific choices.

The right combination of material, geometry and process makes the difference. Final performance is confirmed for the selected product and application.

Low weight

Lightweight components can simplify handling and installation, depending on the selected design.

Corrosion resistance

Resin and reinforcement are selected around moisture, chemicals and the service environment.

Electrical insulation

Insulating components can be configured for power and rail applications to agreed requirements.

HIGH STRENGTH

Components are engineered for structural loads, with strength and stiffness verified against project requirements.

FLAME RETARDANT

Resin systems can be formulated to meet specific fire safety standards and smoke emission requirements.

WEATHERING RESISTANCE

Materials are selected to withstand UV exposure, temperature fluctuations and long-term outdoor conditions.

Made to your drawings

Dimensions, tolerances, fixing points and interfaces are reviewed before manufacture.

Surface options

Discuss colour, texture, anti-slip finish and coating requirements for the selected product.

Process flexibility

Pultrusion, SMC molding, vacuum infusion and hand lay-up support different component geometries.

Assembly support

Profiles and matching fittings can be coordinated into complete access and protection systems.

Quality review

Material, dimensions, finish and inspection requirements are confirmed for the project.

Project-led supply

Quantity, packing, assembly scope and delivery destination are part of the project review.

Vorbește cu Dingchang

Hai să-ți construim următorul proiect.

Împărtășiți aplicația, desenele și cerințele dvs. Echipa noastră vă va ajuta să dezvoltați soluția compozită potrivită.

Shandong Dingchang materiale compozite Co, Ltd.

WhatsApp +86 17515190958
Adresă

Parcul industrial de înaltă tehnologie Wucheng, orașul Sinvsi,
Județul Wucheng, Dezhou, Shandong, China

Spune-ne despre proiectul tău

Trimiteți cerințele dvs. folosind formularul de mai jos.

官网询盘