{"id":191,"date":"2026-10-13T03:04:55","date_gmt":"2026-10-13T03:04:55","guid":{"rendered":"https:\/\/sddcfrp.com\/product\/base-station-radomes\/"},"modified":"2026-11-27T01:27:32","modified_gmt":"2026-11-27T01:27:32","slug":"base-station-radomes","status":"publish","type":"product","link":"https:\/\/sddcfrp.com\/ro\/produs\/base-station-radomes\/","title":{"rendered":"Sta\u021bia de baz\u0103 FRP Radomes"},"content":{"rendered":"<!-- gs-stylemanager -->\n\n\n<div class=\"dcat-content\">\n<div class=\"dcdi-content-panel dcdi-panel-overview\">\n<h2>Product Overview<\/h2>\n\n\n<p>O carcas\u0103 de protec\u021bie pentru antenele sta\u021biei de baz\u0103 fabricate din plastic armat cu fibr\u0103 de sticl\u0103 (FRP\/material compozit din fibr\u0103 de sticl\u0103).<\/p>\n\n\n<p>Compared with conventional metal protective covers of equivalent dimension and mechanical strength, the FRP radome is primarily selected for high electromagnetic wave permeability and low signal attenuation. It protects internal antenna assemblies against outdoor weather, salt-spray corrosion, dust and mechanical impact, and is widely used for macro-base-station sites, rooftop deployments and urban beautification projects.<\/p>\n\n\n<p>Final shell geometry, mounting interface, guaranteed electrical-performance indexes and accessories shall be confirmed according to the approved project specification.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-features\">\n<h2>Key Features<\/h2>\n\n\n<p>FRP composite material with low dielectric loss for high signal transmittance, minimizing impact on antenna radiation performance<\/p>\n\n\n<p>Excellent weather-resistance: UV-resistant, anti-aging, suitable for long-term outdoor exposure under extreme temperature conditions<\/p>\n\n\n<p>Light-weight and high-specific-strength composite structure, reducing load on tower and rooftop mounting supports; easy for transportation and field installation<\/p>\n\n\n<p>Outstanding corrosion resistance against salt spray, acid and alkali, applicable for coastal, industrial and high-humidity environments<\/p>\n\n\n<p>Shell shape, wall thickness, colour and mounting structure configurable according to site aesthetic requirements and electrical specifications<\/p>\n\n\n<p>Sealing structure prevents ingress of rainwater and dust; surface protective coating matched to local installation environment<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-spec\">\n<h2>Reference Specifications<\/h2>\n\n\n<p class=\"dcat-note\">Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.<\/p>\n\n\n<div class=\"dcat-table\">\n<table>\n<tbody>\n<tr>\n<th>Parameter<\/th>\n\n\n<th>Available Configuration<\/th>\n<\/tr>\n\n\n<tr>\n<td>Product Type<\/td>\n\n\n<td>FRP base-station antenna radome<\/td>\n<\/tr>\n\n\n<tr>\n<td>Shell Material<\/td>\n\n\n<td>Fiberglass-reinforced plastic (FRP \/ GRP)<\/td>\n<\/tr>\n\n\n<tr>\n<td>Shell Construction<\/td>\n\n\n<td>According to approved project design<\/td>\n<\/tr>\n\n\n<tr>\n<td>Applicable Frequency Range<\/td>\n\n\n<td>Project-specified (customized for 2G\/3G\/4G\/5G frequency bands)<\/td>\n<\/tr>\n\n\n<tr>\n<td>Dimension &amp; Wall Thickness<\/td>\n\n\n<td>Customized per antenna outline and electrical requirements<\/td>\n<\/tr>\n\n\n<tr>\n<td>Dielectric Constant<\/td>\n\n\n<td>Confirmed in approved technical datasheet<\/td>\n<\/tr>\n\n\n<tr>\n<td>Insertion Loss<\/td>\n\n\n<td>Project-specified guaranteed value<\/td>\n<\/tr>\n\n\n<tr>\n<td>Wind-load Resistance<\/td>\n\n\n<td>Configured for local maximum wind speed requirement<\/td>\n<\/tr>\n\n\n<tr>\n<td>Flame-retardant Grade<\/td>\n\n\n<td>Project-specified<\/td>\n<\/tr>\n\n\n<tr>\n<td>Surface Finish<\/td>\n\n\n<td>UV-resistant surface, custom colour<\/td>\n<\/tr>\n\n\n<tr>\n<td>Mounting Method<\/td>\n\n\n<td>Pole-mount \/ rooftop-mount \/ wall-mount or project-specified<\/td>\n<\/tr>\n\n\n<tr>\n<td>Installation Environment<\/td>\n\n\n<td>Outdoor, coastal, industrial or project-specified<\/td>\n<\/tr>\n\n\n<tr>\n<td>Accessories<\/td>\n\n\n<td>Mounting brackets, fasteners, sealing components configured per approved specification<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-spec\">\n<h2>Reference performance<\/h2>\n\n\n<p class=\"dcat-note\">Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.<\/p>\n\n\n<div class=\"dcat-table\">\n<table>\n<tbody>\n<tr>\n<th>No.<\/th>\n\n\n<th>Parameter Name<\/th>\n\n\n<th>Unit<\/th>\n\n\n<th>Required Value<\/th>\n\n\n<th>Remarks<\/th>\n<\/tr>\n\n\n<tr>\n<td>1<\/td>\n\n\n<td>Volume Resistivity<\/td>\n\n\n<td>\u03a9m<\/td>\n\n\n<td>\u226510\u00b9\u00b3<\/td>\n\n\n<td>Acc.to GB\/T 1410-2006\/IEC 60093 1980<\/td>\n<\/tr>\n\n\n<tr>\n<td>2<\/td>\n\n\n<td>Flexural Strength<\/td>\n\n\n<td>Mpa<\/td>\n\n\n<td>\u2265200<\/td>\n\n\n<td>Acc.to GB1449 or ASTM D790<\/td>\n<\/tr>\n\n\n<tr>\n<td>3<\/td>\n\n\n<td>Impact Strength<\/td>\n\n\n<td>KJ\/m\u00b2<\/td>\n\n\n<td>\u2265120<\/td>\n\n\n<td>Acc.to GB\/T 1451-2005<\/td>\n<\/tr>\n\n\n<tr>\n<td>4<\/td>\n\n\n<td>Glass Fiber Volume Content<\/td>\n\n\n<td>%<\/td>\n\n\n<td>\u226530<\/td>\n\n\n<td>Acc.to ASTM D3171<\/td>\n<\/tr>\n\n\n<tr>\n<td>5<\/td>\n\n\n<td>Degree of Cure<\/td>\n\n\n<td>%<\/td>\n\n\n<td>\u226595<\/td>\n\n\n<td>Acc.to GB\/T 2576<\/td>\n<\/tr>\n\n\n<tr>\n<td>6<\/td>\n\n\n<td>Electric Breakdown Strength<\/td>\n\n\n<td>KV\/mm<\/td>\n\n\n<td>\u226510<\/td>\n\n\n<td>Acc.to GB 1408 or IEC 243<\/td>\n<\/tr>\n\n\n<tr>\n<td>7<\/td>\n\n\n<td>Tracking Resistance<\/td>\n\n\n<td>V<\/td>\n\n\n<td>600<\/td>\n\n\n<td>GB\/T 4207-2012\/IEC 60112-2009<\/td>\n<\/tr>\n\n\n<tr>\n<td>8<\/td>\n\n\n<td>Water Absorption<\/td>\n\n\n<td>%<\/td>\n\n\n<td>\u22640.2<\/td>\n\n\n<td>Acc.to GB1462 or ASTM D570<\/td>\n<\/tr>\n\n\n<tr>\n<td>9<\/td>\n\n\n<td>Flame Retardancy<\/td>\n\n\n<td><\/td>\n\n\n<td>V-0<\/td>\n\n\n<td>GB\/T 2408-2008\/IEC 60695-11-10:1999<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-features\">\n<h2>Standards and Testing<\/h2>\n\n\n<p>Domestic-market configurations can be reviewed against applicable requirements of YD\/T 4757-2024, related composite-material and communication-equipment specifications.<\/p>\n\n\n<p>Export-oriented configurations can be reviewed against relevant IEC composite-material standards or other project-specified standards. Final compliance shall depend on approved design, guaranteed performance values and agreed test documentation.<\/p>\n\n\n<p>Routine tests may include:<\/p>\n\n\n<p>Appearance and dimensional inspection<\/p>\n\n\n<p>Dielectric-property test (dielectric constant, dielectric loss factor)<\/p>\n\n\n<p>Insertion loss and electromagnetic-performance verification<\/p>\n\n\n<p>Mechanical load \/ wind-load simulation test<\/p>\n\n\n<p>UV-aging and weathering-resistance test<\/p>\n\n\n<p>Water-proof &amp; dust-proof sealing inspection<\/p>\n\n\n<p>Type tests, special environmental tests and third-party inspection can be agreed prior to production when required.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-overview\">\n<h2>Applications<\/h2>\n\n\n<p>Macro cellular communication base stations<\/p>\n\n\n<p>Rooftop and tower-top communication sites<\/p>\n\n\n<p>Urban site beautification &amp; camouflage reconstruction projects<\/p>\n\n\n<p>Coastal and high-corrosion-area communication networks<\/p>\n\n\n<p>Industrial park wireless-coverage sites<\/p>\n\n\n<p>5G-oriented new-construction communication projects<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-overview\">\n<h2>Selecting an FRP Base Station Antenna Radome<\/h2>\n\n\n<p>The actual working performance of an FRP radome depends on guaranteed electrical indexes, operating frequency band, local meteorological conditions (wind speed, ultraviolet intensity, salt-spray level) and antenna physical outline.<\/p>\n\n\n<p>Selection should therefore be based on approved dielectric-property, insertion-loss and mechanical-load data rather than only relying on nominal product type.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-cta\">\n<h2>Request a Quotation<\/h2>\n\n\n<p>Please provide applicable frequency band, outer dimension constraints, required insertion-loss index, wind-load requirement, applicable standard, installation environment, shell colour &amp; appearance requirements, accessory list, quantity and project destination.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-cta\">\n<h2>Discuta\u021bi proiectul dvs<\/h2>\n\n\n<p>Share your drawing, quantity, application and delivery destination with our team.<\/p>\n\n\n<a class=\"dcat-cta\" href=\"\/ro\/#enquiry\">Solicita\u021bi o cota\u021bie<\/a>\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>O carcas\u0103 de protec\u021bie pentru antenele sta\u021biei de baz\u0103 fabricate din plastic armat cu fibr\u0103 de sticl\u0103 (FRP\/material compozit din fibr\u0103 de sticl\u0103).<\/p>","protected":false},"featured_media":742,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":".dcat-content{font-family:Roboto,Arial,sans-serif;color:#233858;max-width:100%;font-size:16px;line-height:1.65}.dcat-content h2{font-family:Roboto,Arial,sans-serif;font-size:var(--wp--preset--font-size--xl,28px);line-height:1.2;color:#0d2255;margin-top:32px;margin-bottom:14px}.dcat-content p{margin-top:0;margin-bottom:16px}.dcat-content ul{padding-left:0;margin:0 0 24px;list-style:none}.dcat-content li{padding:9px 0;border-bottom:1px solid #e1e8ee}.dcat-content .dcat-table{overflow-x:auto;max-width:100%;margin:18px 0 28px}.dcat-content table{width:100%;border-collapse:collapse;font-size:14px;line-height:1.5}.dcat-content td,.dcat-content th{padding:12px 14px;text-align:left;border:1px solid #dce4ed;min-width:100px}.dcat-content th{background:#edf3f8;color:#0d2255}.dcat-content .dcat-cta{display:inline-block;padding:14px 24px;background:#0755ff;color:#fff;font-weight:700;text-decoration:none;margin:12px 0}.dcat-content .dcat-note{font-size:13px;line-height:1.5;color:#597088;background:#edf3f8;padding:16px;margin-top:18px;margin-bottom:20px}@media(max-width:600px){.dcat-content{font-size:15px}.dcat-content h2{font-size:24px;line-height:1.2}.dcat-content td,.dcat-content th{padding:9px;font-size:12px}}","rank_math_title":"Custom FRP Base Station Radomes for Antennas | Dingchang","rank_math_description":"Specify FRP base station radomes as protective antenna housings. Review fiberglass composite geometry and mounting requirements with Dingchang.","rank_math_canonical_url":"","rank_math_focus_keyword":"FRP base station radomes"},"product_brand":[],"product_cat":[25,18],"product_tag":[],"class_list":["post-191","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-power-parts","product_cat-frp-compression-molded-products","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/product\/191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/comments?post=191"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/media\/742"}],"wp:attachment":[{"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/media?parent=191"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/product_brand?post=191"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/product_cat?post=191"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sddcfrp.com\/ro\/wp-json\/wp\/v2\/product_tag?post=191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}