{"id":189,"date":"2026-10-13T03:04:52","date_gmt":"2026-10-13T03:04:52","guid":{"rendered":"https:\/\/sddcfrp.com\/product\/clamp-covers\/"},"modified":"2026-11-27T01:27:38","modified_gmt":"2026-11-27T01:27:38","slug":"clamp-covers","status":"publish","type":"product","link":"https:\/\/sddcfrp.com\/tr\/urun\/clamp-covers\/","title":{"rendered":"SMC FRP Clamp Covers"},"content":{"rendered":"<!-- gs-stylemanager -->\n\n\n<div class=\"dcat-content\">\n<div class=\"dcdi-content-panel dcdi-panel-overview\">\n<h2>Product Overview<\/h2>\n\n\n<p>A protective housing cover manufactured from SMC fiberglass-reinforced plastic composite for overhead power line clamps.<\/p>\n\n\n<p>Compared with conventional metal clamp covers of equivalent dimensions, the FRP clamp cover adopts high-performance fiberglass composite material to deliver excellent electrical insulation, corrosion-resistance and UV-aging resistance. It is designed to shield overhead line clamps against ultraviolet radiation, rain, salt-fog, dust and external mechanical impact. This product is well-suited for overhead distribution networks operating in coastal, saline-alkali, industrial-polluted and long-term outdoor exposure environments.<\/p>\n\n\n<p>Final structural dimension, mounting interface, material performance grade and accessories shall be confirmed in accordance with the approved project specification.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-features\">\n<h2>Key Features<\/h2>\n\n\n<p>High-strength SMC fiberglass-reinforced plastic composite for outstanding insulation and anti-corrosion performance.<\/p>\n\n\n<p>Adaptable to overhead distribution lines under coastal salt-fog, saline-alkali and heavily polluted outdoor conditions.<\/p>\n\n\n<p>Integral moulded structure; sealed fit minimizes exposure of internal clamp hardware to ambient atmosphere.<\/p>\n\n\n<p>Optimized wall thickness and reinforcing ribs to resist external mechanical impact and deformation.<\/p>\n\n\n<p>Mounting interface, opening size and fixing configuration selected to match the corresponding line clamp dimensions.<\/p>\n\n\n<p>Flame-retardant grade, UV-resistant additive and surface finish configured for the local installation environment.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-spec\">\n<h2>Reference Specifications<\/h2>\n\n\n<p class=\"dcat-note\">Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.<\/p>\n\n\n<div class=\"dcat-table\">\n<table>\n<tbody>\n<tr>\n<th>Parameter<\/th>\n\n\n<th>Available Configuration<\/th>\n<\/tr>\n\n\n<tr>\n<td>Type<\/td>\n\n\n<td>FRP clamp cover<\/td>\n<\/tr>\n\n\n<tr>\n<td>Core material<\/td>\n\n\n<td>SMC fiberglass-reinforced plastic composite<\/td>\n<\/tr>\n\n\n<tr>\n<td>Structure construction<\/td>\n\n\n<td>According to approved project drawing<\/td>\n<\/tr>\n\n\n<tr>\n<td>Reference dimension range<\/td>\n\n\n<td>Custom-made to match line-clamp specification<\/td>\n<\/tr>\n\n\n<tr>\n<td>Rated applicable voltage<\/td>\n\n\n<td>Project-specified (0.4kV-35kV typical)<\/td>\n<\/tr>\n\n\n<tr>\n<td>Flame retardant class<\/td>\n\n\n<td>Custom grade as required<\/td>\n<\/tr>\n\n\n<tr>\n<td>Complete model designation<\/td>\n\n\n<td>Confirmed according to selected construction<\/td>\n<\/tr>\n\n\n<tr>\n<td>Guaranteed mechanical &amp; dielectric performance<\/td>\n\n\n<td>Defined in approved technical data sheet<\/td>\n<\/tr>\n\n\n<tr>\n<td>Mounting form<\/td>\n\n\n<td>Snap-fit \/ bolt-fastened, project-specified<\/td>\n<\/tr>\n\n\n<tr>\n<td>Installation<\/td>\n\n\n<td>Outdoor overhead power line<\/td>\n<\/tr>\n\n\n<tr>\n<td>Accessories<\/td>\n\n\n<td>Fasteners, sealing gaskets configured per approved specification<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-spec\">\n<h2>Reference performance<\/h2>\n\n\n<p class=\"dcat-note\">Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.<\/p>\n\n\n<div class=\"dcat-table\">\n<table>\n<tbody>\n<tr>\n<th>No.<\/th>\n\n\n<th>Parameter Name<\/th>\n\n\n<th>Unit<\/th>\n\n\n<th>Required Value<\/th>\n\n\n<th>Remarks<\/th>\n<\/tr>\n\n\n<tr>\n<td>1<\/td>\n\n\n<td>Volume Resistivity<\/td>\n\n\n<td>\u03a9m<\/td>\n\n\n<td>\u226510\u00b9\u00b3<\/td>\n\n\n<td>Acc.to GB\/T 1410-2006\/IEC 60093 1980<\/td>\n<\/tr>\n\n\n<tr>\n<td>2<\/td>\n\n\n<td>Flexural Strength<\/td>\n\n\n<td>Mpa<\/td>\n\n\n<td>\u2265200<\/td>\n\n\n<td>Acc.to GB1449 or ASTM D790<\/td>\n<\/tr>\n\n\n<tr>\n<td>3<\/td>\n\n\n<td>Impact Strength<\/td>\n\n\n<td>KJ\/m\u00b2<\/td>\n\n\n<td>\u2265120<\/td>\n\n\n<td>Acc.to GB\/T 1451-2005<\/td>\n<\/tr>\n\n\n<tr>\n<td>4<\/td>\n\n\n<td>Glass Fiber Volume Content<\/td>\n\n\n<td>%<\/td>\n\n\n<td>\u226530<\/td>\n\n\n<td>Acc.to ASTM D3171<\/td>\n<\/tr>\n\n\n<tr>\n<td>5<\/td>\n\n\n<td>Degree of Cure<\/td>\n\n\n<td>%<\/td>\n\n\n<td>\u226595<\/td>\n\n\n<td>Acc.to GB\/T 2576<\/td>\n<\/tr>\n\n\n<tr>\n<td>6<\/td>\n\n\n<td>Electric Breakdown Strength<\/td>\n\n\n<td>KV\/mm<\/td>\n\n\n<td>\u226510<\/td>\n\n\n<td>Acc.to GB 1408 or IEC 243<\/td>\n<\/tr>\n\n\n<tr>\n<td>7<\/td>\n\n\n<td>Tracking Resistance<\/td>\n\n\n<td>V<\/td>\n\n\n<td>600<\/td>\n\n\n<td>GB\/T 4207-2012\/IEC 60112-2009<\/td>\n<\/tr>\n\n\n<tr>\n<td>8<\/td>\n\n\n<td>Water Absorption<\/td>\n\n\n<td>%<\/td>\n\n\n<td>\u22640.2<\/td>\n\n\n<td>Acc.to GB1462 or ASTM D570<\/td>\n<\/tr>\n\n\n<tr>\n<td>9<\/td>\n\n\n<td>Flame Retardancy<\/td>\n\n\n<td><\/td>\n\n\n<td>V-0<\/td>\n\n\n<td>GB\/T 2408-2008\/IEC 60695-11-10:1999<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-features\">\n<h2>Standards and Testing<\/h2>\n\n\n<p>Domestic-market configurations shall comply with relevant requirements of GB\/T 1404.1, GB\/T 2570 and corresponding power-fitting standards.<\/p>\n\n\n<p>Export-oriented configurations may reference IEC 61952 or other project-specified standards. Final compliance shall be subject to approved design, guaranteed performance values and agreed test documentation.<\/p>\n\n\n<p>Routine tests may include:<\/p>\n\n\n<p>Visual and dimensional inspection<\/p>\n\n\n<p>Dielectric strength &amp; insulation resistance test<\/p>\n\n\n<p>Mechanical impact test<\/p>\n\n\n<p>Fastening \/ assembly fit check<\/p>\n\n\n<p>Appearance check after high-low temperature cycling test<\/p>\n\n\n<p>Type tests, special environmental ageing tests and third-party inspection can be agreed prior to production upon request.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-overview\">\n<h2>Applications<\/h2>\n\n\n<p>Urban and rural overhead distribution networks<\/p>\n\n\n<p>Coastal, salt-fog and saline-alkali power transmission sections<\/p>\n\n\n<p>Industrial\u2011area overhead lines with chemical atmospheric pollution<\/p>\n\n\n<p>Overhead lines requiring long-term outdoor anti-corrosion protection<\/p>\n\n\n<p>Distribution-network upgrade projects for overhead fitting insulation improvement<\/p>\n\n\n<p>New-energy power-plant overhead outgoing line systems<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-overview\">\n<h2>Selecting an FRP Clamp Cover<\/h2>\n\n\n<p>The service-life and protective effectiveness of the FRP clamp cover depend on matching dimensions with the actual line clamp, guaranteed material performance grade, local environmental conditions and operating voltage level.<\/p>\n\n\n<p>Selection shall therefore be based on approved mechanical-dielectric data and on-site fitting dimension parameters rather than model designation alone.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-cta\">\n<h2>Request a Quotation<\/h2>\n\n\n<p>Please provide applicable rated voltage, matched line-clamp type &amp; dimension, required flame-retardant \/ anti-UV grade, applicable standard, installation environment conditions, supporting accessory requirements, quantity and project destination.<\/p>\n\n<\/div>\n\n\n<div class=\"dcdi-content-panel dcdi-panel-cta\">\n<h2>Discuss Your Project<\/h2>\n\n\n<p>Share your drawing, quantity, application and delivery destination with our team.<\/p>\n\n\n<a class=\"dcat-cta\" href=\"\/tr\/#enquiry\">Request a Quote<\/a>\n<\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>A protective housing cover manufactured from SMC fiberglass-reinforced plastic composite for overhead power line clamps.<\/p>","protected":false},"featured_media":736,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_gspb_post_css":".dcat-content{font-family:Roboto,Arial,sans-serif;color:#233858;max-width:100%;font-size:16px;line-height:1.65}.dcat-content h2{font-family:Roboto,Arial,sans-serif;font-size:var(--wp--preset--font-size--xl,28px);line-height:1.2;color:#0d2255;margin-top:32px;margin-bottom:14px}.dcat-content p{margin-top:0;margin-bottom:16px}.dcat-content ul{padding-left:0;margin:0 0 24px;list-style:none}.dcat-content li{padding:9px 0;border-bottom:1px solid #e1e8ee}.dcat-content .dcat-table{overflow-x:auto;max-width:100%;margin:18px 0 28px}.dcat-content table{width:100%;border-collapse:collapse;font-size:14px;line-height:1.5}.dcat-content td,.dcat-content th{padding:12px 14px;text-align:left;border:1px solid #dce4ed;min-width:100px}.dcat-content th{background:#edf3f8;color:#0d2255}.dcat-content .dcat-cta{display:inline-block;padding:14px 24px;background:#0755ff;color:#fff;font-weight:700;text-decoration:none;margin:12px 0}.dcat-content .dcat-note{font-size:13px;line-height:1.5;color:#597088;background:#edf3f8;padding:16px;margin-top:18px;margin-bottom:20px}@media(max-width:600px){.dcat-content{font-size:15px}.dcat-content h2{font-size:24px;line-height:1.2}.dcat-content td,.dcat-content th{padding:9px;font-size:12px}}","rank_math_title":"Specify FRP Clamp Covers for Overhead Lines | Dingchang","rank_math_description":"Protect overhead power line clamps with FRP clamp covers. Review the SMC fiberglass composite housing shape and installation details for the line.","rank_math_canonical_url":"","rank_math_focus_keyword":"FRP clamp covers"},"product_brand":[],"product_cat":[25,18],"product_tag":[],"class_list":["post-189","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-power-parts","product_cat-frp-compression-molded-products","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/product\/189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/comments?post=189"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/media\/736"}],"wp:attachment":[{"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/media?parent=189"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/product_brand?post=189"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/product_cat?post=189"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/sddcfrp.com\/tr\/wp-json\/wp\/v2\/product_tag?post=189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}