Elevated railway tracks with side railings and a distant city skyline

SMC Third Rail Cover Support Clips

Explore product features and specifications. Share your drawing to discuss a tailored solution.

SMC Third Rail Cover Support Clips

One-piece SMC FRP support clips position third rail protective covers in metro and urban transit systems. Clip geometry and mounting interfaces are matched to the approved protection assembly.

Dingchang / Sales Manager +86 17515190958
Get in touch

Description

Product Overview

Cover Support Clip is a critical fixture designed for third rail protection systems in metro and urban transit projects. Fabricated via one-piece compression molding from high-performance SMC(FRP) composite, this integrated support component delivers reliable positioning and stable backing for third rail protective covers. It features superior dielectric strength, vibration resistance and corrosion stability for tunnel and outdoor transit environments.

Key Features

1. Lightweight and high strength FRP material, sturdy and durable with low self-weight.

2. Excellent insulation property, prevents electric leakage & short circuit risk for 3rd rail system.

3. Superior corrosion resistance, resistant to acid, alkali, moisture and salt spray.

4. Weather-proof, UV stable, long service life under outdoor & tunnel environment.

5. Low thermal conductivity, good fire retardant performance.

6. Non-magnetic, will not interfere with signal & electromagnetic system of metro.

7. Easy cutting, drilling and installation; low maintenance cost.

8. Dimensional stable, no deformation under long-term load and temperature change.

Quality & testing

Standards and Testing

All products are manufactured in strict accordance with national composite material industry standards and molded product specifications. We implement incoming raw material inspection, in-process online monitoring, and full inspection of finished products to ensure stable and consistent product quality. We can provide a full set of third-party test reports, covering mechanical properties, insulation properties, water absorption test, flame retardancy test and dimensional inspection. For special engineering projects, we can provide customized test parameters and technical parameter verification to meet project bidding and engineering acceptance requirements.

Applications & project requirements

Applications

1. Metro & urban rail transit third-rail protection system

2. Subway tunnel, elevated urban rail line power-supply protection

3. Transit depot & stabling yard exposed conductor rail protection

Request a Quotation

Please provide your requirements, including drawings, cross-sectional dimensions, length, quantity, usage environment, as well as special requirements such as insulation, UV resistance, flame retardancy, or chemical corrosion resistance.

Discuss Your Project

Share your drawing, quantity, application and delivery destination with our team.

Request a Quote
Specifications & configuration

Review the available product information and project-specific configurations below.

View specifications →

Specifications & configuration

Product information for your technical review. Final dimensions and requirements are confirmed for the selected configuration.

Reference Specifications

Reference configurations from the supplied product information. Final dimensions, material grade, test scope and acceptance criteria are confirmed for the selected product.

Item No. Parameter Name Unit Technical Specification - Required Value Remarks
1 Volume Resistivity Ω·m ≥10¹³ GB/T 1410-2006/IEC 60093 1980
2 Flexural Strength Mpa ≥200 GB1449 or ASTM D790
3 Impact Strength KJ/m² ≥120 GB/T 1451-2005
4 Glass Fiber Volume Content % ≥30 ASTM D3171
5 Degree of Cure % ≥95 GB/T 2576
6 Electrical Breakdown Strength KV/mm ≥10 GB 1408 or IEC 243
7 Tracking Resistance V 600 GB/T 4207-2012/IEC 60112-2009
8 Water Absorption % ≤0.2 GB1462 or ASTM D570
9 Flame Retardancy — V-0 GB/T 2408-2008/IEC 60695-11-10:1999

Material and manufacturing

FRP advantages. Project-specific choices.

The right combination of material, geometry and process makes the difference. Final performance is confirmed for the selected product and application.

Low weight

Lightweight components can simplify handling and installation, depending on the selected design.

Corrosion resistance

Resin and reinforcement are selected around moisture, chemicals and the service environment.

Electrical insulation

Insulating components can be configured for power and rail applications to agreed requirements.

HIGH STRENGTH

Components are engineered for structural loads, with strength and stiffness verified against project requirements.

FLAME RETARDANT

Resin systems can be formulated to meet specific fire safety standards and smoke emission requirements.

WEATHERING RESISTANCE

Materials are selected to withstand UV exposure, temperature fluctuations and long-term outdoor conditions.

Made to your drawings

Dimensions, tolerances, fixing points and interfaces are reviewed before manufacture.

Surface options

Discuss colour, texture, anti-slip finish and coating requirements for the selected product.

Process flexibility

Pultrusion, SMC molding, vacuum infusion and hand lay-up support different component geometries.

Assembly support

Profiles and matching fittings can be coordinated into complete access and protection systems.

Quality review

Material, dimensions, finish and inspection requirements are confirmed for the project.

Project-led supply

Quantity, packing, assembly scope and delivery destination are part of the project review.

Talk to Dingchang

Let’s build your next project.

Share your application, drawings and requirements. Our team will help you develop the right composite solution.

Shandong Dingchang Composite Materials Co., Ltd.

WhatsApp +86 17515190958
Address

Wucheng High-tech Industrial Park, Sinvsi Town,
Wucheng County, Dezhou, Shandong, China

Tell us about your project

Send your requirements using the form below.

官网询盘